Measuring holding power: how our pull tester works
Every magnet has a holding force, but how much does it really hold? With our own pull tester, we can measure it precisely when needed. Here’s how it works.
Every magnet in our webshop has a holding force listed: approx. 7 kg, approx. 37 kg, or even approx. 350 kg. But how do you actually arrive at such a figure? And how much will that magnet really hold in your particular situation? To measure this precisely when necessary, we have our own testing setup in Nuenen: a motorised pull tester with a digital force gauge.
How we determine holding force
The holding force of our products is calculated for ideal conditions: the magnet is pulled perpendicularly off a thick, flat, bare steel plate. This allows you to compare magnets fairly. Want to know the exact figure? We can measure it on our own pull tester upon request. Also read How is the holding force of a magnet determined?
In practice, conditions are almost never ideal. That is why it is useful that we can also measure it for real.
How our pull tester works
A pull tester essentially does what you do when you pull a magnet off a steel plate, but in a highly controlled manner:
- The magnet is placed on a steel plate.
- It is connected to the digital force gauge via a hook or rope.
- A motor pulls the magnet slowly and straight upwards, always at the same speed.
- The force gauge records the highest force just before the magnet lets go. That is the holding force.

Because the motor pulls rather than a hand, every measurement is exactly the same. No jerks, no pulling at an angle, and a result that can be repeated.
Why measuring is useful
The holding force depends heavily on the situation. With the pull tester, we can see what happens when:
- the steel is thinner: a thin plate cannot fully absorb the force of a strong magnet;
- there is a layer of paint or varnish in between: even a half-millimetre gap requires a lot of force;
- the surface is not flat: less contact means less holding force;
- you apply a sideways load: a magnet will slide off a vertical wall at approximately 15 to 20% of the perpendicular holding force.
Measuring upon request
Are you working on a project where the fit must be exact, for example a closure, a tensioning system, or a product you are manufacturing in series? Upon request, we will re-measure every magnet in our range for you. Contact us and tell us what you would like to know.
Please keep in mind that even a measured value remains theoretical. It applies to the conditions of the measurement, using our steel and our setup. It may turn out differently in your application, so always allow a generous margin.
A standard testing method for all magnets
We want to be able to record the holding force even more reliably in the future, for all shapes in our range: from disc and block magnets to ring magnets and pot magnets. We will be working on this together with a mechanical engineering graduate in the near future. As soon as there are results, you can read about them here.
Until then: allow a generous margin
Use the stated holding force as a comparison between magnets, and always allow a safety margin of 30 to 50% in practice. Not sure which magnet you need? Use the Magnet Advisor or read What is the strongest magnet?